The power cuts out, your APC UPS starts beeping and you’re nowhere near your desk. Without software, your PC keeps running until the battery goes flat, then dies in the middle of whatever it was doing. APC PowerChute Serial Shutdown stops that. It’s a free software agent from Schneider Electric that watches your UPS over a USB or serial cable and shuts your computer down safely before the battery runs out.
It’s also the direct replacement for both PowerChute Personal Edition and PowerChute Business Edition, so if you went looking for either of those, this is where you end up. The latest release, version 1.6, adds SmartConnect cloud monitoring for Back-UPS models. Version 1.5 didn’t offer that option on our APC BX1600MI.
Here at Techrater UK, we’ve pulled everything into one guide. You’ll see what the software replaces, how it works, what it can do, how to install it and what to try when it won’t see your UPS. If you only want alerts by email, we also have a separate guide on how to configure APC PowerChute Serial Shutdown email notifications.
Quick Answer
Short on time? Here’s the lot in a few lines.
- What it is: a free software agent that monitors an APC UPS and shuts down your PC or server safely during a power cut.
- What it replaces: PowerChute Personal Edition and PowerChute Business Edition.
- Works with: APC Back-UPS, Smart-UPS and Easy UPS Online (3kVA and below), connected by USB or serial cable.
- Runs on: Windows 10, Windows 11, Windows Server 2022 and 2025, plus Hyper-V. Linux is supported for Smart-UPS and Easy UPS Online only. There’s no macOS version.
- Newest feature: version 1.6 lets a Back-UPS connect to SmartConnect for remote monitoring.
- Not for: UPS units managed over the network with a Network Management Card. Those need PowerChute Network Shutdown instead.
What Is APC PowerChute Serial Shutdown?
APC PowerChute Serial Shutdown is UPS monitoring and configuration software for the computer your UPS is plugged into. Schneider Electric, which owns APC, calls it an agent because it runs quietly as a background service rather than as a window you keep open. You set it up and check on it through a web browser.
It’s built for homes, home offices and small to medium-sized businesses that rely on their computers. When the mains supply fails, it handles the unattended, graceful shutdown for you, so open files are saved and Windows closes down properly instead of losing power halfway through a task. It also tracks the state of the UPS and reports on energy use.
Why You Need It
A UPS only keeps your PC running for a short while. A small unit might give you a few minutes at half load, and less when you’re pushing it. The battery can’t tell your PC what’s happening, and that’s the gap this software fills.
- Safe shutdowns when you’re away: the PC closes itself down even if nobody’s in the room.
- Protection for your data: work is saved and the operating system shuts down cleanly, rather than being cut off mid-write.
- Gentler on your hardware: a clean shutdown beats a sudden power loss, which suits expensive PCs and servers.
- Visibility: you can see battery charge, load and runtime at a glance, and check the event log after an outage.
What Does PowerChute Serial Shutdown Replace?
Schneider Electric released PowerChute Serial Shutdown in March 2023 to take over from its older home and business software. PowerChute Personal Edition was discontinued at the end of December 2024 and is no longer available to download. PowerChute Business Edition is also being replaced by the same software. As a result, one modern, secure tool now covers all three UPS families.
| PowerChute Software Compared | |||
|---|---|---|---|
| Software | Connection | Used With | Status |
| PowerChute Personal Edition | USB | Back-UPS and home PCs | Discontinued, replaced by Serial Shutdown |
| PowerChute Business Edition | USB or serial | Smart-UPS, Easy UPS and local servers | Replaced by Serial Shutdown |
| PowerChute Serial Shutdown | USB or serial | Back-UPS, Smart-UPS and Easy UPS Online | Current software for directly connected UPS units |
| PowerChute Network Shutdown | Network card | Network-managed Smart-UPS | Separate product for network setups |
Still running the old Personal Edition? Schneider Electric recommends uninstalling it and installing Serial Shutdown in its place.
Who Needs PowerChute Serial Shutdown?
It suits any setup where the UPS cable plugs straight into the computer you want to protect.
Home and Home Office Users
If you own a Back-UPS or Back-UPS Pro connected by USB to a desktop or workstation, this is your software. It does the job Personal Edition used to do.
Small and Medium Businesses
IT admins with a Smart-UPS or Easy UPS connected by USB or serial to a local server will find it replaces Business Edition. It also copes with Hyper-V hosts.
Who Can Skip It
- Network-managed UPS owners: if your Smart-UPS has a Network Management Card and you want shutdowns controlled over the network, use PowerChute Network Shutdown.
- Mac users: there’s no macOS version, but macOS already includes UPS shutdown settings (see the installation section below).
- Anyone who just wants an alarm: the UPS will still beep and run on battery without any software. You only need this to shut a computer down for you.
Compatible UPS Models and Operating Systems
PowerChute Serial Shutdown works with three APC UPS families. Smart-UPS and Easy UPS Online are covered up to 3kVA, and every one needs a serial or USB cable to the protected computer.
| PowerChute Serial Shutdown Compatibility | |||
|---|---|---|---|
| UPS Family | Connection | Operating Systems | Notes |
| Back-UPS | USB | Windows only | All models with a USB port. The model code is on the label at the back of the UPS. |
| Smart-UPS (3kVA and below) | USB or serial | Windows and Linux | Direct connection, no Network Management Card. Scheduled shutdown available. |
| Easy UPS Online (3kVA and below) | USB or serial | Windows and Linux | Scheduled shutdown available. |
Windows
Version 1.6 comes as a 64-bit download for Windows 10, Windows 11, Windows Server 2022, Windows Server 2025 and Microsoft Hyper-V.
Linux
Linux builds are available, with Red Hat Enterprise Linux and SUSE Linux Enterprise Server as the supported distributions. However, Linux only works with Smart-UPS and Easy UPS Online. A Back-UPS isn’t supported on Linux, so check before you plan a Linux home server around one.
macOS
There’s no Mac version. When an APC UPS is connected by USB, macOS detects it and offers shutdown options in its own battery or energy settings, so you don’t need extra software.
Not sure your model qualifies? Schneider Electric lists which APC UPS models work with PowerChute over USB or serial.
How APC PowerChute Serial Shutdown Works
The software sits between your UPS and your operating system. The UPS knows about the power. The agent knows what to do about it.
- The UPS watches the mains. It reports its status to the agent over the USB or serial cable all the time.
- The power fails. The UPS switches to battery and tells the agent it’s now on battery.
- The agent applies your rule. You choose whether it reacts straight away, after a set time, or when the remaining runtime drops below a limit.
- Your command file runs. If you’ve set one up, it closes applications or saves data first.
- The operating system shuts down. Windows closes cleanly before the battery is empty.
- Power returns. Depending on the UPS and outlet group settings, the protected system can restart on its own, so nobody has to be on site.
On a desktop PC, you may also need to set the BIOS so the computer powers on when mains power returns. Otherwise it can stay off after an unattended shutdown.
You manage everything in a web browser. Open it from the Windows Start menu, or type https://servername:6547 or the agent’s IP address and port into a browser on another computer on your network.
PowerChute Serial Shutdown Features
Here’s what you get once the software is installed.
Unattended, Graceful Shutdown
This is the headline feature. The agent saves open files and shuts the OS down safely before the UPS battery runs out. It also supports an unattended start-up, so the computer can come back by itself afterwards.
Flexible Shutdown Triggers
You decide when a shutdown starts. The Shutdown settings give you four choices for a power outage.
| PowerChute Shutdown Triggers | ||
|---|---|---|
| Option | What It Does | Suits |
| Immediately | Starts shutting down as soon as the UPS goes on battery | Servers and PCs you want safe at the first sign of trouble |
| After a set time on battery | Waits for the time you choose before shutting down | Riding out short power blips |
| At the runtime limit | Shuts down when remaining runtime falls below the number of seconds you set | Getting the most from the battery |
| Do not shut down | Relies on the low runtime warning, which fires when runtime drops below your application and OS shutdown time | Setups where something else handles shutdown |
The OS shutdown time defaults to a value that depends on the UPS, usually 60 or 120 seconds.
Pre-Shutdown Command Files
Before the operating system closes, the agent can run command files you set up. Use them to close applications, stop services or save data. The longest command file among your shutdown events sets how long the agent waits before it starts the OS shutdown.
UPS Monitoring and Status
The dashboard shows system status, power status and battery status, including battery charge, load and runtime in real time. Further menus cover battery management, diagnostics and UPS settings such as transfer voltages and alarm options.
Events, Logging and Notifications
Every power event is logged, and the agent can send you email alerts. We’ve covered the full process in our guide to configuring APC PowerChute Serial Shutdown email notifications, including the Gmail settings.
Energy Management
Built-in energy metering reports usage in kWh, the cost in your local currency and CO2 in kilograms or pounds. It picks a default country and average energy cost from your computer’s settings, and you can enter your own cost per kWh. The agent connects to the internet to fetch some of that data, so don’t be surprised to see outbound traffic.
Self-Tests and Diagnostics
You can run battery self-tests and alarm tests, and see the results, from the same web interface. Regular tests are the easiest way to catch a tired battery before you need it.
Scheduled Shutdown
Smart-UPS and Easy UPS Online owners also get scheduled shutdown, handy for switching equipment off outside working hours.
Secure Web Interface
The interface uses HTTPS and a login you create during installation. Three failed logins lock the account for two minutes, and sessions end after 15 minutes of inactivity by default. It’s available in seven languages: English, Chinese, French, German, Italian, Brazilian Portuguese and Spanish.
What’s New in Version 1.6: SmartConnect Monitoring
Version 1.6 adds a feature many Back-UPS owners have wanted. You can now connect a compatible Back-UPS to EcoStruxure IT SmartConnect, Schneider Electric’s cloud portal, through a link called PowerChute Link. As a result, you get real-time visibility of power conditions, UPS status and system health from anywhere, rather than only from the PC it’s plugged into.
On our APC BX1600MI, version 1.5 had no SmartConnect option at all, so if you were wondering where it had gone, you need version 1.6 or later. This release also fixes four security vulnerabilities across Back-UPS, Smart-UPS and Easy UPS, so it’s worth installing even if you don’t want cloud monitoring.
Remote monitoring is especially handy for kiosks, point-of-sale systems and self-service terminals, where you need to know what the power is doing without being on site.
What You Need for SmartConnect
- A Back-UPS from the BK, BR, BE or BX series with a USB port.
- PowerChute Serial Shutdown version 1.6 or later, on a Windows computer.
- An internet connection. The computer needs to reach smartconnect.apc.com in a browser and TCP port 443 on the two Schneider Electric cloud addresses listed in their guide.
- A PowerChute Link subscription, or the free 30-day trial.
Setting it up takes four steps. Check your model, install version 1.6 or later, make sure the computer can reach the required addresses, then create a PowerChute Link connection and start your trial. Schneider Electric’s page on connecting a Back-UPS to SmartConnect with PowerChute Link walks through it.
One catch: PowerChute Link isn’t offered in the USA, Canada, Costa Rica, India, mainland China or Japan. The UK isn’t on that list.
How to Install PowerChute Serial Shutdown
Installation takes a few minutes. Follow these steps in order.
- Connect the cable. Plug the UPS into the computer using the USB or serial cable, directly into a port on the computer. Don’t use a USB hub.
- Download the software. It’s a free download from Schneider Electric. Grab the Windows (x64) version, or visit the PowerChute Serial Shutdown page for Linux downloads and release notes.
- Run the installer. Keep the UPS connected so the installer can detect it. If you have to pick your UPS from a list, choose Back-UPS for a Back-UPS model.
- Create your login. The username needs 6 to 128 characters. The password needs 8 to 128 characters, with an uppercase letter, a lowercase letter and a number or special character, and it can’t contain the username.
- Work through the setup wizard. It takes you through Preferences and then Shutdown Settings. You can revisit either screen at any time.
- Open the web interface. Choose PowerChute Serial Shutdown from the Windows Start menu, or browse to
https://servername:6547. - Accept the certificate warning. The first time, your browser says the connection isn’t private. That’s because the agent uses a self-signed certificate. Choose Advanced, then proceed to the site. You can replace the certificate with your own later.
- Test it. Run a self-test from the Diagnostics menu. Once everything is saved and nothing important is running, you can also unplug the UPS from the wall to watch the shutdown happen.
Cable Requirements
- USB: use the cable that came with the UPS, or a USB-IF certified replacement. Connect it straight to the computer, not through a hub or docking station.
- Serial: use the serial cable APC supplies. Standard RS-232 cables won’t work, because APC uses its own pinout.
- One computer only: connect just one computer to the UPS data port at a time.
Troubleshooting PowerChute Serial Shutdown
Most problems come down to the cable, a stopped service or a setting in Windows. Work through these in order.
Windows Troubleshooting
- Check the service. Press Windows key + R, type
services.mscand press Enter. Make sure the “APC PBE Agent” service is running. If it’s stopped, right-click it and choose Start. - Check the cable. Connect it straight to the computer, not through a hub, and try a different USB port.
- Look in Device Manager. Find the APC device under “Batteries” or “HID UPS Battery”. If it shows a warning icon, uninstall the driver and reconnect the cable.
- Turn off USB selective suspend. Go to Power Options, Change plan settings, Change advanced power settings, then USB settings, and set USB selective suspend to Disabled.
- Turn off Green Mode. If your UPS has a Green Mode or energy-saving mode, it can interfere with communication. Switch it off from the front panel or LCD.
UPS Not Detected After Installing or Upgrading
If the software can’t find a UPS that worked before, try a clean install. Uninstall PowerChute Serial Shutdown, leave the UPS connected, then install it again so it detects the UPS automatically. Still nothing? Connect the UPS to a different computer and install there. That tells you whether the fault is the UPS or the first computer.
Serial-to-USB Adaptors
Schneider Electric recommends a serial-to-serial connection where you can. With some serial-to-USB adaptors, such as those using the Prolific PL2303 driver, the agent can’t report a disconnected cable. If that happens, reconnect the plug to the correct USB port and restart the “APC PBE Agent” service.
Forgotten Username or Password
You can reset your login through the configuration file. Add a [Credentials] section with a new username= and password= to pcssconfig.ini in the agent folder, then restart the “APC PBE Agent” service.
Test Emails Not Arriving
Check the pcss.log file. Common causes are wrong credentials, a server identity mismatch, proxy problems, an unreachable SMTP server or an unsupported protocol. Our email notifications guide shows working Gmail settings.
Linux Troubleshooting
On Linux, run lsusb and look for an “American Power Conversion” entry. If it’s missing, check the physical connection and try another port. In version 1.3 and later, if communication doesn’t come back after you disconnect and reconnect the UPS, restart the daemon or the operating system. On systemd distributions, that means sudo systemctl stop PBEAgent, then sudo systemctl start PBEAgent.
Collecting Files for Support
Still stuck? In the interface, open About, then Troubleshooting. The agent creates a zip file called PcssFiles followed by a timestamp in its agent folder. On Windows, that’s usually C:\Program Files\APC\PowerChute Serial Shutdown\agent. Send it to Schneider Electric support along with your UPS model.
PowerChute Serial Shutdown Specifications
| APC PowerChute Serial Shutdown Specifications | |
|---|---|
| Developer | Schneider Electric (APC) |
| Software Type | UPS monitoring, configuration and graceful shutdown agent |
| Latest Version | 1.6 |
| Licence | Free download |
| Replaces | PowerChute Personal Edition and PowerChute Business Edition |
| Compatible UPS | APC Back-UPS, Smart-UPS and Easy UPS Online |
| Connection to UPS | USB or serial cable |
| Windows Support | Windows 10, Windows 11, Windows Server 2022 and 2025, Hyper-V |
| Linux Support | RHEL and SLES, for Smart-UPS and Easy UPS Online only |
| macOS Support | None (built-in macOS UPS settings instead) |
| User Interface | Web interface over HTTPS, default port 6547 |
| Languages | English, Chinese, French, German, Italian, Brazilian Portuguese, Spanish |
| Energy Management | kWh, cost and CO2 reporting |
| Diagnostics | Self-tests and alarm tests |
| Remote Monitoring | SmartConnect via PowerChute Link (version 1.6 or later, Back-UPS) |
Alternatives to PowerChute Serial Shutdown
You don’t have to use it, but there’s nothing quite like it for an APC UPS on Windows.
- Windows’ built-in battery handling: a USB Back-UPS shows up in Windows as a battery, so Windows power settings can take basic action at low battery. However, Windows has no native shutdown for a serial-connected UPS, and you lose the event log, energy reports and shutdown command files.
- macOS built-in support: the only option on a Mac, and a perfectly good one.
- apcupsd: a free, open-source alternative that suits tinkerers and Linux users. On Windows it can only run a single instance, so it’s no good for several UPS units.
- PowerChute Network Shutdown: the right choice when the UPS has a network card and several servers need to shut down from one UPS.
Conclusion
APC PowerChute Serial Shutdown does one important job well. It turns a UPS from a battery that buys you a few minutes into a system that looks after your computer when you can’t. It’s free, it covers Back-UPS, Smart-UPS and Easy UPS Online, and it replaces both PowerChute Personal Edition and PowerChute Business Edition in a single download.
If you own a Back-UPS, version 1.6 is the one to get, because it adds SmartConnect remote monitoring and security fixes. So download it from Schneider Electric, plug the cable straight into your computer, and run through the setup wizard. Then set up email alerts with our APC PowerChute Serial Shutdown email notifications guide, so you hear about the next outage even if you’re out. You can also read more on Schneider Electric’s PowerChute Serial Shutdown page.
Questions People Ask
What Is PowerChute Serial Shutdown?
It’s free APC software that monitors a UPS connected to your computer by USB or serial cable. During a power cut, it saves your work and shuts the computer down safely before the battery runs out.
Is PowerChute Serial Shutdown Free?
Yes. You can download it from Schneider Electric at no charge. The optional PowerChute Link cloud monitoring needs a subscription after a free 30-day trial.
What Does PowerChute Serial Shutdown Replace?
It replaces PowerChute Personal Edition and PowerChute Business Edition. Personal Edition was discontinued at the end of December 2024.
Which UPS Models Work With PowerChute Serial Shutdown?
It works with APC Back-UPS models that have a USB port, plus Smart-UPS and Easy UPS Online models up to 3kVA connected by USB or serial. Smart-UPS units managed through a Network Management Card need PowerChute Network Shutdown instead.
Does PowerChute Serial Shutdown Work on Windows 11?
Yes. Version 1.6 supports Windows 10, Windows 11, Windows Server 2022 and 2025, and Hyper-V.
Does PowerChute Serial Shutdown Work on Mac or Linux?
There’s no Mac version, because macOS has its own built-in UPS shutdown support. Linux is supported, but only with Smart-UPS and Easy UPS Online. A Back-UPS doesn’t work with it on Linux.
Which Version Adds SmartConnect?
Version 1.6. It lets a compatible Back-UPS connect to the SmartConnect portal through PowerChute Link. On our APC BX1600MI, version 1.5 didn’t have the option.
Does the SmartConnect Option Cost Anything?
You can start with a free 30-day trial of PowerChute Link, then choose a subscription if you want to keep it. Schneider Electric sets the terms, so check its page for the current offer.
Can I Use a USB Hub With My UPS?
Avoid it. Connect the cable straight to a port on the computer, because hubs and docking stations can break communication between the UPS and the software.
Will My Computer Restart After the Power Comes Back?
It can. The agent supports unattended start-up, and it depends on your UPS and outlet group settings. On a desktop PC, you may also need to set the BIOS to power on when mains power returns.
How Do I Open the PowerChute Serial Shutdown Interface?
Choose PowerChute Serial Shutdown from the Windows Start menu. To reach it from another computer, enter https://servername:6547 or the agent’s IP address and port in a browser. Expect a certificate warning the first time.
Can One UPS Shut Down Several Computers?
Not with this software. A USB or serial cable links the UPS to one computer at a time. To protect several machines from one UPS, you need a network card and PowerChute Network Shutdown.
Why Can’t PowerChute See My UPS?
Check that the “APC PBE Agent” service is running, plug the cable directly into the computer and try another port. Then check Device Manager, turn off USB selective suspend and switch off Green Mode on the UPS. If it still fails, uninstall and reinstall the software with the UPS connected.
How Do I Reset My PowerChute Password?
Add a [Credentials] section with a new username and password to the pcssconfig.ini file in the agent folder. Then restart the “APC PBE Agent” service.
Is PowerChute Serial Shutdown Safe to Use?
The interface uses HTTPS with a login, and version 1.6 fixes four security vulnerabilities. It does use a self-signed certificate, so your browser warns you the first time. You can swap in your own certificate if you prefer.