A UPS is brilliant at keeping the power on, but it can’t tell you something’s wrong when you’re nowhere near it. A battery that needs replacing, a firmware update you never got round to, a locked-up router that needs a reboot: you normally find out about all of them on site, or when the lights go out. APC SmartConnect fixes that. It’s a cloud service from Schneider Electric that lets you remotely track, optimise, upgrade and maintain your APC Smart-UPS from a web browser, a tablet or your phone.
Here at Techrater UK, we’ve pulled everything about APC SmartConnect into one guide. You’ll see what it is, what each plan gives you, how it works, which Smart-UPS models are compatible, how to set it up and what to try when a UPS won’t connect. Back-UPS owners aren’t left out either, because a compatible Back-UPS can now join in through PowerChute Link.
Quick Answer
Short on time? Here’s the lot in a few lines.
- What it is: EcoStruxure IT SmartConnect, a cloud portal for remotely monitoring and managing APC UPS units.
- Works with: Smart-UPS models that have a built-in SmartConnect Ethernet port (SMT, SMX, SMTL, SMC, SCL and SRTL prefixes). Compatible Back-UPS models connect through PowerChute Link.
- Main benefits: power status from anywhere, event alerts, one-click firmware updates, remote diagnostics and, on the Advanced plan, remote power cycling.
- Setup: plug the UPS into your network, switch it on, wait a few minutes, then register it by scanning the QR code on the label.
- Trial: newly registered Smart-UPS units get a free six-month trial of the Standard plan.
- Network needs: an IPv4 DHCP server, a 10/100 Mbps port and access to Schneider Electric’s cloud on TCP port 443.
- Not for: shutting down computers. SmartConnect watches the UPS, whereas PowerChute software looks after safe shutdowns.
What Is APC SmartConnect?
APC SmartConnect is a cloud-based web portal for remotely watching and controlling APC Smart-UPS units. Schneider Electric, which owns APC, builds the connection into the UPS itself through a dedicated SmartConnect Ethernet port. As a result, you don’t need to buy a network card or install anything on a server. You plug the UPS into your network, register it, and it appears in your online dashboard.
From there you can check the status of each UPS, get notified about power and UPS events, install firmware updates and run diagnostics. The portal also works on tablets and phones, so you can check on a UPS from the sofa as easily as from the office.
Who APC SmartConnect Is For
Schneider Electric aims it at businesses with distributed IT, unattended sites and managed service providers. In practice, it suits anyone whose UPS lives somewhere they don’t visit every day.
- Small businesses: a UPS in the comms cupboard is one less thing to walk over and check.
- Multi-site organisations: shops, clinics, branch offices and schools can all appear in one dashboard, in a map or list view.
- IT support companies: you can watch customers’ power from your desk and sort problems before the customer rings.
- Home labs and home offices: a compatible Smart-UPS gives you alerts and firmware updates without extra hardware.
What SmartConnect Doesn’t Do
SmartConnect monitors the UPS. It doesn’t tell your PC or server to shut down when the battery runs low. For that, you still need PowerChute software on the computer, such as our guide to APC PowerChute Serial Shutdown, or a network card with PowerChute Network Shutdown. The two work well together, because SmartConnect tells you about the outage while PowerChute looks after the computer.
Benefits of APC SmartConnect
The pitch comes down to three things: knowing what your power’s doing, keeping the UPS up to date and fixing problems without a trip on site.
Know Your Sites’ Power Status From Anywhere
The secure web dashboard shows the state of every registered UPS at a glance. You can see which units are healthy, which are on battery and which need attention, in a map or a list. Custom tags help you sort devices by site, building or customer, and utility power quality analytics show how clean your incoming supply is. For a UPS you can’t see, that’s a real comfort.
Automated, One-Click Smart-UPS Firmware Updates
Firmware is how APC fixes bugs and closes security holes, and it’s the update most people forget. SmartConnect delivers new firmware to registered, connected units and alerts you when one’s ready. On a paid plan, you can install it remotely with a single click from the portal. Without a paid plan, the firmware still reaches the UPS, but someone has to start the install from the UPS front panel.
Remote Power Cycling Helps Eliminate Onsite Reboot Visits
The classic call is “the router’s frozen, can someone switch it off and on?” With the Advanced plan, you can name your outlet groups, then reboot a group remotely to power cycle whatever’s plugged into it. Frozen routers, switches and modems get a restart without anybody travelling, and you stop asking a receptionist to crawl under a desk.
Longer UPS Life and Better Planning
Alerts for event storms and temperature swings come with suggested remote settings that reduce wear on the equipment. Asset registration, lifecycle tracking and downloadable reports help you plan renewals, replacements, warranties and maintenance. Power metrics also support the case for upgrades when you’re asking for budget.
Fewer Site Visits and Better Sustainability
Fewer visits save time and travel costs. Schneider Electric also points out that every cloud-connectable Smart-UPS carries a Green Premium label, which it says supports sustainability goals.
How APC SmartConnect Works
The idea’s simple. The UPS talks directly to Schneider Electric’s cloud, and you talk to the cloud through a web browser.
- The UPS connects out. Through its SmartConnect Ethernet port, it opens an encrypted connection to Schneider Electric’s cloud services over TCP port 443.
- You register it. Scanning the QR code on the UPS links the unit to your Schneider Electric account.
- The cloud collects the data. Status, events, battery health and power conditions appear in your web portal dashboard.
- You get alerts. Notifications go out by email, with Slack and Teams options, when something needs attention.
- You send commands back. Firmware installs, self-tests, sensitivity changes and outlet group reboots travel from the portal to the UPS, provided you allow them on the UPS itself.
The SmartConnect Control Setting
That last point matters. Every cloud-enabled Smart-UPS has a SmartConnect Control (or SmartConnect access) setting, and it decides what the cloud’s allowed to do. You change it on the UPS, using the LCD menu. On SCL models, you use a slide switch near the network port instead.
- Enable, No Control: the default on most Smart-UPS units. You can view data and receive notifications, but the portal can’t change anything.
- Enable, With Control: needed for remote firmware installs, Advanced plan features, remote self-tests and sensitivity adjustment.
Put simply, if a remote action fails, check this setting first. Because you need to be at the UPS to change it, it’s also a handy safeguard against anyone making changes remotely without your say-so.
APC SmartConnect Features
Here’s what the portal gives you, and which plan unlocks it. The next section covers the plans in full.
Dashboard and Device Tracking
Every registered UPS appears in one dashboard, in a map or list view, with its health and status. You can tag devices, download inventory and renewal reports, and share devices with other users on the Standard and Advanced plans.
Notifications and Event Logs
Pre-configured email notifications tell you about power and UPS events, and you can redirect them to Slack or Teams. Event logs and uptime summaries let you look back over what happened and when.
Remote Diagnostics and Self-Tests
You can run a UPS self-test and an audible alarm test from the portal, and adjust the voltage sensitivity, which controls how readily the UPS switches to battery. You can also set or change the battery installation date from the cloud, so the portal knows how old the battery is.
Remote Firmware Updates
One-click installs push the latest firmware to a UPS without anyone touching it. Automated alerts tell you when an update’s available.
Remote Outlet Group Control
The Advanced plan adds outlet group naming, remote reboots of a group and load shedding, which switches off non-essential equipment to stretch the battery during an outage. You also get guidance on which loads to put on which outlet group.
Security Options
Two-factor authentication is available on every plan, and the platform follows current industry standards for collecting and handling data. We cover the network side further down.
Compatible APC Smart-UPS Family
SmartConnect works with Smart-UPS models that have a built-in SmartConnect Ethernet port. The cloud-enabled units cover a wide spread of the range, from around 500VA up to 3kVA, in tower and rack-mount shapes. Schneider Electric identifies them by their model prefix.
| APC SmartConnect Compatible Smart-UPS Models | |||
|---|---|---|---|
| Prefix | Example Models | Display | Notes |
| SMT | SMT1500IC, SMT1500RMI2UC | 5-button LCD | Tower and rack-mount line-interactive units. Restart the network interface from the display. |
| SMX | Model codes ending in C | 5-button LCD | Line-interactive units with a fully interactive LCD. Restart the network interface from the display. |
| SMTL | SMTL750RM2UC | 5-button LCD | Rack-mount models. Restart the network interface from the display. |
| SRTL | Model codes ending in C | Touch screen | Restart under Configuration, Communication, then SmartConnect Restart. |
| SMC | SMC1000C | 3-button icon LCD | Compact units. Model codes end in L or C. |
| SCL | SCL500RM1UC | Status indicators | Enable SmartConnect Control with the slide switch near the network port. |
| Back-UPS (BK, BR, BE, BX) | BX1600MI and similar | Varies | Not Smart-UPS. Connects through PowerChute Link and a USB cable, so it’s covered in its own section below. |
How to Check Your Model
Look at the model code on the label. Cloud-enabled Smart-UPS units have a SmartConnect Ethernet port on the unit, and the model codes usually end in C, such as SMT1500IC or SMT1500RMI2UC. If your UPS has no SmartConnect Ethernet port, it isn’t compatible, no matter which family it comes from. Schneider Electric also keeps a list of cloud-enabled Smart-UPS units on its website.
What About Older Smart-UPS Models?
Older units without the SmartConnect port can’t join in. If you rely on one, you’d need a UPS network management card and a different Schneider Electric monitoring platform, such as EcoStruxure IT. Replacing the UPS with a cloud-enabled model is often the simpler route when it’s due a battery swap anyway.
APC SmartConnect Plans and Free Trial
There are three levels: Basic, Standard and Advanced. Every newly registered Smart-UPS starts with a free six-month trial of the Standard plan, so you can try the lot before you pay for anything.
| APC SmartConnect Plans Compared | |||
|---|---|---|---|
| Feature | Basic | Standard | Advanced |
| UPS status and health viewing | Yes | Yes | Yes |
| Map or list view and device tags | Yes | Yes | Yes |
| Downloadable inventory reports | Yes | Yes | Yes |
| Two-factor authentication | Yes | Yes | Yes |
| Event logs and uptime summaries | No | Yes | Yes |
| Email, Slack and Teams notifications | No | Yes | Yes |
| Remote self-test and diagnostics | No | Yes | Yes |
| Voltage sensitivity adjustment | No | Yes | Yes |
| Device sharing with other users | No | Yes | Yes |
| Firmware updates | Install at the UPS | Remote, one-click | Remote, one-click |
| Outlet group naming | No | No | Yes |
| Remote outlet group reboot | No | No | Yes |
| Load shedding | No | No | Yes |
What Happens When the Trial Ends
If you don’t buy a plan, the UPS drops back to Basic monitoring. It carries on protecting your equipment exactly as before, and you can still see its status on the dashboard. However, you lose notifications, event log recording and remote diagnostic tests, and firmware installs go back to the UPS front panel. Buying a Standard or Advanced plan restores full portal access.
Choosing Between Standard and Advanced
Standard covers monitoring, alerts and remote firmware, which is plenty for most offices. Choose Advanced when you want to reboot equipment remotely, for example at a site with no IT staff, or to automate load shedding. Plans are bought per UPS, and Schneider Electric and its resellers sell them as licences that run for a year or longer. Check the SmartConnect plans page for the current terms and offers.
APC SmartConnect Requirements
Before you plug anything in, check your network can do the following. Most home routers meet all of it without any changes, but office networks with strict firewalls or proxies often need a tweak.
- A SmartConnect Ethernet port: it’s the only hardware requirement on a Smart-UPS.
- A Schneider Electric account: you create one when you sign up to the portal.
- An IPv4 DHCP server: the UPS needs one to get an address, and your router almost certainly does that already.
- TCP port 443 to the cloud: the UPS must reach Schneider Electric’s cloud services directly. If you use a proxy such as ZScaler, add a firewall rule that allows the connection and skips the proxy’s packet inspection.
- A 10/100 Mbps port: the UPS doesn’t support gigabit speeds. On a gigabit switch port that isn’t set to auto-negotiate, the connection can fail.
- MTU of at least 336 bytes: your routers and switches need to support it, which every normal network does.
- Physical access, once: you need to be at the UPS to scan its QR code and set the SmartConnect Control permission.
Schneider Electric lists the exact cloud addresses in its network requirements for the SmartConnect portal, so pass that to your network administrator if you have one.
How to Set Up APC SmartConnect
Setup takes about a quarter of an hour, and most of that’s waiting for the UPS to find the cloud. Follow these steps in order. Schneider Electric’s own Getting Started with SmartConnect guide covers the same ground.
- Prepare the UPS. Connect the battery, then plug in the utility power cord.
- Connect the network. Plug an Ethernet cable from your network into the SmartConnect Ethernet port on the UPS. Use the dedicated SmartConnect port, not a network card slot.
- Switch the UPS on. Then wait. It can take 5 to 15 minutes for the UPS to establish its connection to the cloud, and you should leave 4 to 5 minutes before you try to register it.
- Create your account. Visit the SmartConnect welcome page and sign up. You create a Schneider Electric account and register your company, or find it if it’s already listed.
- Register the UPS. Log in to the portal on a phone or tablet, choose Add, then QR Code Scan, and point the camera at the QR code label. The label can be on the top, front, side or rear of the UPS, and rack-mount units often have it on the front or rear panel. The portal’s built-in scanner is the quickest route.
- Set the sensitivity. The portal asks how sensitive the UPS should be to on-battery conditions. Pick a setting, then choose Next and Finish.
- Enable SmartConnect Control. If you want remote firmware installs, self-tests or Advanced plan features, change the SmartConnect Control setting on the UPS to Enable, With Control.
- Set up notifications. Choose who gets alerts and which events matter, then check the device appears on your dashboard.
No QR Code or Label?
You’ve two fallbacks. If your phone can’t scan, choose Product Codes in the portal and type in the Product ID and Product Key instead. If the label’s missing on an SMT model, open the About menu on the UPS display and read the UPS MAC and Product Key entries. A UPS that’s already linked to another Schneider Electric account can’t be added, so ask the previous owner to remove it first.
Watch the Video
Schneider Electric’s video on setting up SmartConnect remote monitoring for APC Back-UPS walks through the Back-UPS route on screen.
SmartConnect for APC Back-UPS
Back-UPS units don’t have a SmartConnect Ethernet port, but they aren’t shut out. A compatible Back-UPS can send its status to SmartConnect through a link called PowerChute Link, which is part of PowerChute Serial Shutdown version 1.6 and later. The UPS stays connected to your Windows computer by USB, and the computer passes the data on to the cloud.
What You Need
- A Back-UPS from the BK, BR, BE or BX series with a USB communication port, such as the one in our APC BX1200MI review.
- PowerChute Serial Shutdown version 1.6 or later on the Windows computer.
- An internet connection. The computer must reach smartconnect.apc.com in a browser, plus TCP port 443 on the two cloud addresses listed in Schneider Electric’s guide.
- A PowerChute Link subscription, or the free 30-day trial that comes with every SmartConnect account for one Back-UPS.
How to Connect a Back-UPS
Install PowerChute Serial Shutdown 1.6 or later, check the computer can reach the cloud, then create a PowerChute Link connection and start your trial. Schneider Electric’s page on connecting a Back-UPS to SmartConnect with PowerChute Link has the detail.
Back-UPS Limits to Know About
PowerChute Link isn’t offered in the USA, Canada, Costa Rica, India, mainland China or Japan. The UK isn’t on that list. Also, the Back-UPS route depends on a computer staying on and connected, whereas a Smart-UPS talks to the cloud by itself. If the PC is off, the cloud loses sight of the UPS.
Troubleshooting APC SmartConnect
Most connection problems come down to patience, the network port or a firewall.
The UPS Won’t Connect to the Cloud
- Wait a little longer. Allow several minutes after powering on and plugging in the cable.
- Check the connection status. On a UPS with a character display, go to Status, then SmartConnect. The display shows a status code that tells you how far the connection has got, and models with icon displays or status indicators show the same information in their own way.
- Check the internet. Make sure the switch or router port the UPS uses has a working internet connection.
- Check the port speed. The UPS only supports 10/100 Mbps, so set a gigabit switch port to auto-negotiate.
- Check the firewall. Confirm TCP port 443 is open to Schneider Electric’s cloud, with no proxy inspection in the way.
- Restart the network interface. On SMT, SMX and SMTL models, do it from the display. On SRTL models, go to Configuration, Communication, SmartConnect Restart, then Yes.
If the status shows Securing (Sc.5) or Prohibited (Sc.8), contact APC customer support. Prohibited means the Ethernet connection isn’t allowed because of a hardware issue or a configuration.
Remote Actions Fail
If self-tests, sensitivity changes, firmware installs or outlet group reboots don’t work, check the SmartConnect Control setting on the UPS. It needs to be on Enable, With Control. Also confirm you’re on a plan that includes the feature, because Basic doesn’t.
Registration Problems
If the QR code won’t scan, use the Product Codes option. If the portal says the device already belongs to someone else, it’s linked to another Schneider Electric account and has to be removed from there first. Schneider Electric’s guide to troubleshooting a SmartConnect UPS connection explains each status code.
Is APC SmartConnect Secure?
Schneider Electric says SmartConnect follows current industry standards for data collection, processing and infrastructure, and publishes a security page on the portal. There are also sensible steps you can take yourself.
- Keep the UPS behind a firewall. Schneider Electric strongly recommends that the device isn’t exposed to the public internet and sits behind a stateful packet inspection firewall.
- Turn on two-factor authentication. It’s free on every plan.
- Leave SmartConnect Control on its default. Only choose Enable, With Control when you need remote actions. Switching it needs physical access to the UPS, so nobody can change it from the cloud.
- Allow the right ciphers. If your firewall inspects encrypted traffic, make sure it allows the connection the UPS uses, or the UPS won’t connect.
APC SmartConnect Specifications
| APC SmartConnect Specifications | |
|---|---|
| Service | EcoStruxure IT SmartConnect, a cloud web portal for APC UPS monitoring |
| Developer | Schneider Electric (APC) |
| Compatible Smart-UPS | Models with a SmartConnect Ethernet port: SMT, SMX, SMTL, SMC, SCL and SRTL |
| Compatible Back-UPS | BK, BR, BE and BX series with USB, through PowerChute Link |
| Connection | Ethernet, 10/100 Mbps, IPv4 DHCP |
| Cloud Access | Direct TCP port 443 to Schneider Electric cloud services |
| Registration | QR code scan or product codes, with physical access to the UPS |
| Interface | Web portal for desktop, tablet and phone |
| Plans | Basic, Standard and Advanced |
| Free Trial | Six months of the Standard plan on newly registered Smart-UPS units; 30 days of PowerChute Link for one Back-UPS |
| Notifications | Email, with Slack and Teams options (Standard and Advanced) |
| Firmware Updates | Remote one-click installs on Standard and Advanced; local install on Basic |
| Remote Power Cycling | Outlet group reboot on Advanced |
| Security | Two-factor authentication, SmartConnect Control permission set at the UPS |
| Not Available | PowerChute Link isn’t offered in the USA, Canada, Costa Rica, India, mainland China or Japan |
Alternatives to APC SmartConnect
SmartConnect isn’t the only way to keep an eye on a UPS, and it isn’t always the right one.
- PowerChute Serial Shutdown: free software that shuts a single computer down safely during a power cut. It pairs nicely with SmartConnect, and it’s the route a Back-UPS uses to reach the cloud.
- PowerChute Network Shutdown: the choice when several servers need to shut down from one network-managed UPS.
- A network management card and EcoStruxure IT: better suited to bigger estates and data centres than a handful of small UPS units.
- Doing nothing: the UPS will still beep, run on battery and protect your kit without any cloud service. You just lose the remote visibility.
Conclusion
APC SmartConnect takes a UPS from something you check when you remember to, to something that tells you when it needs you. If you own a compatible Smart-UPS, setup takes minutes, the six-month Standard trial lets you try everything before paying and the remote firmware updates alone make it worth a go. The Advanced plan then earns its keep at sites where nobody’s around to reboot a frozen router.
Check your UPS has the SmartConnect Ethernet port, sort the network settings and register it with the QR code. Back-UPS owners can get in on the act with PowerChute Serial Shutdown 1.6 and PowerChute Link, and our PowerChute email notifications guide covers alerts on the computer side. You can start on the APC SmartConnect website.
Questions People Ask
What Is APC SmartConnect?
It’s a cloud web portal from Schneider Electric for remotely monitoring and managing APC Smart-UPS units. You see UPS status, get event notifications, install firmware and run diagnostics from a browser or phone.
Is APC SmartConnect Free?
It starts free. Newly registered Smart-UPS units get a six-month trial of the Standard plan, and a Basic monitoring level carries on afterwards. Notifications, event logs, remote diagnostics and remote firmware installs need a paid Standard or Advanced plan.
Which APC Smart-UPS Models Work With SmartConnect?
Models with a built-in SmartConnect Ethernet port, which means the SMT, SMX, SMTL, SMC, SCL and SRTL prefixes. If your UPS doesn’t have the port, it isn’t compatible.
Does APC SmartConnect Work With Back-UPS?
Yes, through PowerChute Link. You need a BK, BR, BE or BX series Back-UPS with USB, PowerChute Serial Shutdown 1.6 or later on a Windows computer and a PowerChute Link subscription or the free 30-day trial.
How Do I Set Up APC SmartConnect?
Plug the UPS into your network through its SmartConnect Ethernet port, switch it on and wait a few minutes. Then sign up at the SmartConnect website and register the UPS by scanning the QR code on its label.
How Long Does It Take for a UPS to Connect to SmartConnect?
Between 5 and 15 minutes after you power it on. Wait 4 to 5 minutes before you try to register it.
Do I Need a Network Card for SmartConnect?
No. Compatible Smart-UPS units have the SmartConnect Ethernet port built in, so no extra accessory is needed.
Can SmartConnect Shut Down My Computer?
No. SmartConnect monitors the UPS and sends you alerts. To shut a computer down safely during a power cut, use PowerChute Serial Shutdown or PowerChute Network Shutdown.
What Is SmartConnect Control?
It’s a setting on the UPS that decides what the cloud can do. Enable, No Control lets you view data and get notifications. Enable, With Control also allows remote firmware installs, self-tests, sensitivity changes and Advanced plan features.
Can I Update Smart-UPS Firmware Remotely?
Yes, on the Standard and Advanced plans, with SmartConnect Control set to Enable, With Control. Without a paid plan, the firmware still arrives, but you start the install at the UPS.
Can I Reboot Equipment Remotely With SmartConnect?
Yes, on the Advanced plan. You can name your outlet groups and reboot a group from the portal, which power cycles whatever’s plugged into it.
What Happens When the Free Trial Ends?
The UPS drops to Basic monitoring. It still protects your equipment and you can view its status, but notifications, event logs and remote diagnostics stop until you buy a plan.
What Network Settings Does SmartConnect Need?
An IPv4 DHCP server, a 10/100 Mbps port and direct access to Schneider Electric’s cloud on TCP port 443. If you use a proxy, add a firewall rule that skips its packet inspection.
Why Won’t My UPS Connect to SmartConnect?
Wait several minutes, check the status code on the display, confirm the internet works on that port and set a gigabit switch port to auto-negotiate. Then check TCP port 443 is open and restart the UPS network interface.
Is APC SmartConnect Secure?
Schneider Electric says it follows current industry security standards, and two-factor authentication is available on every plan. Keep the UPS behind a firewall rather than exposed to the internet, as Schneider Electric recommends.
Does SmartConnect Work on a Phone?
Yes. The web portal works on tablets and phones, and you can use a phone’s camera to scan the QR code when you register a UPS.